MARC details
000 -LEADER |
fixed length control field |
02178nam a22002297a 4500 |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20210918121534.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
190209b ||||| |||| 00| 0 eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER |
International Standard Book Number |
9783659719172 |
040 ## - CATALOGING SOURCE |
Transcribing agency |
VITAP |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER |
Edition number |
23rd |
Classification number |
620 RAH |
100 ## - MAIN ENTRY--PERSONAL NAME |
9 (RLIN) |
10848 |
Personal name |
Rahman, M. Lutfor |
245 ## - TITLE STATEMENT |
Title |
Closed Loop Pulsating Heat Pipe : |
Remainder of title |
Heat Transfer Characteristics of a Closed Loop Pulsating Heat Pipe with Fin and Wire Insert / |
Statement of responsibility, etc. |
M. Lutfor Rahman, Rasel A. Sultan and Mohammad Ali |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Germany |
Name of publisher, distributor, etc. |
LAP Lambert Academic Publishing |
Date of publication, distribution, etc. |
2018 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
151p. : ill. ; |
Dimensions |
22cm |
500 ## - GENERAL NOTE |
General note |
It includes Appendix and Tables. |
521 ## - TARGET AUDIENCE NOTE |
Target audience note |
Pulsating heat pipes (PHP) have created a newer arena and promising possibilities as passive devices for heat transfer applications, especially suited for thermal management of electronics. A closed loop pulsating heat pipe (CLPHP) made of copper with 2.5 mm ID and 3 mm OD with fin in the condenser section is used in the present work to evaluate the heat transfer performances where the evaporation section is 50 mm, adiabatic section is 120 mm and condensation section is 80 mm. The attempt is to analyze and compare the effects on the heat transfer performances of CLPHP with finned, fin-inserted and un-finned condenser section with inclination angle of 0⁰ (vertical), 30⁰ and 45⁰. Methanol and Ethanol are used as working fluids with 50% filling ratio in CLPHP with 8 loops during the experimentation. The experimental results indicate a strong influence of gravity and thermo physical properties of the working fluid on the performance of the CLPHP studied with different orientation and heat load. The results demonstrate the effect of fin and fin-insert used in condenser section, the input heat flux, inclination angle orientation and physio-chemical properties of the working fluid. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
9 (RLIN) |
10849 |
Topical term or geographic name entry element |
Electronic cooling; Pulsating heat pipe (PHP) |
700 ## - ADDED ENTRY--PERSONAL NAME |
9 (RLIN) |
10850 |
Personal name |
Sultan, Rasel A. |
700 ## - ADDED ENTRY--PERSONAL NAME |
9 (RLIN) |
10851 |
Personal name |
Ali, Mohammad |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
<a href="https://www.lap-publishing.com/catalog/details/store/es/book/978-3-659-71917-2/closed-loop-pulsating-heat-pipe?search=9783659719172">https://www.lap-publishing.com/catalog/details/store/es/book/978-3-659-71917-2/closed-loop-pulsating-heat-pipe?search=9783659719172</a> |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Reference Book |
Classification part |
620 |
Call number suffix |
RAH |